Bosch Evolution HDS7052U Conversion Manual - Page 4

Browse online or download pdf Conversion Manual for Oven Bosch Evolution HDS7052U. Bosch Evolution HDS7052U 32 pages. Dual fual ranges
Also for Bosch Evolution HDS7052U: Installation Instructions Manual (36 pages)

Conversion

Before You Begin

Tools and Parts Needed

Parts Included

General Information

Always Provide Adequate
Gas Supply
Preparation

Procedure

English 2
7 mm Socket Driver w/ 3" extension
Torx (T20)-head screwdriver
Adjustable Wrench
Flathead Screwdriver (1/8" or smaller)
Phillips Head Screwdriver
Conversion Kit Instructions
Conversion Sticker
4 LP Orifices
This appliance is shipped from the factory for use with natural gas. Use this kit to
convert the appliance for LP gas use if necessary. Observe the following:
Be sure the range is converted for use with the appropriate gas before using it.
This appliance is designed to operate at a pressure of 10" of water column when
used with LP gas.
When checking for proper operation of the regulator, the inlet pressure must be at
least 1" greater than the operating (manifold) pressure above. When converting
for LP gas use, the pressure supplied to the regulator must be between 11" and
14" of water column. See step 2 "Convert Pressure Regulator from 5" to 10"
W.C.", next page.
The pressure regulator located in the inlet of the range manifold must remain in
the supply line.
Use a flexible metal appliance connector or rigid pipe to connect the Range to the
gas supply. The connector should have an I.D. of 1/2" and be 5' in length (Excep-
tion: Maximum connector length in Massachusetts installations is 3'). In Canada,
the connector must be single wall metal and not longer than 6'.
CAUTION: Turn off Gas and Electricity
Before proceeding with the conversion; shut off the gas supply to the appliance
prior to disconnecting the electrical power.
1. Turn all control knobs to the "OFF" position.
2. Shut off the outside propane tank gas valve to the range.
3. Remove range power cord from electrical outlet or turn breaker off at breaker
box