Bosch Evolution HDS7052U Conversion Manual - Page 8
Browse online or download pdf Conversion Manual for Oven Bosch Evolution HDS7052U. Bosch Evolution HDS7052U 32 pages. Dual fual ranges
Also for Bosch Evolution HDS7052U: Installation Instructions Manual (36 pages)
Conversion
Test the Installation
Test for Gas Leaks
Apply Leak Detection Fluid
Test Electric Ignition
Test Cooktop Burners:
English 6
1. Use a 1/2" wrench to turn orifice clockwise until it stops (2 1/2 - 3 turns).
Unlike the broil burner orifice, the bake burner orifice should be tightened as
far as it will go in order to ensure that complete conversion has occurred.
Air Shutter
Bake Orifice
Natural Gas Setting
Leak testing is to be conducted by the installer according to the instructions given
in this section.
Turn on Gas. Apply a non-corrosive leak detection fluid to all joints and fittings in
the gas connection between the shutoff valve and the range. Include gas fittings
and joints in the range if connections may have been disturbed during installation.
Bubbles appearing around fittings and connections indicate a leak.
If a leak appears, turn off supply line gas shutoff valve and tighten connections.
Retest for leaks by turning on the supply line gas shutoff valve. When leak check
is complete (no bubbles appear), test is complete. Wipe off all detection fluid resi-
due.
CAUTION: Never check for leaks with a flame.
Do not continue to the next step until all leaks are eliminated.
Turn on power at breaker
Caution: If the display flashes and beeps, the polarity of the wiring may be
reversed. Reversed polarity can damage the range and can result in electrical
shock hazard. Immediately switch off power at the breaker and return to installa-
tion instructions.
Each burner must be tested for proper lighting, proper flame characteristics on the
low setting and proper flame characteristics on the high setting.
Test for proper ignition:
Figure 2: Bake Orifice
Fully seated
LP Gas Setting
Figure 3: Bake Orifice Conversion