3.
Following pressure testing and flushing procedures the diaphragms should be examined
and replaced if necessary to ensure the integrity of the unit prior to use in production.
4.
Turning the main adjusting screw clockwise will increase the spring pressure on the unit
and therefore the fluid back pressure on the paint system.
Turning the screw anti-clockwise will decrease back pressure.
The Pilot controlled unit operates in the same way, an increase in pilot air pressure
increases the system back pressure.
5 Adjust the spring (or pilot air pressure) until the desired system fluid back pressure is
achieved on the pressure gauge in the BPR inlet pipework.
77-3247 R2.2
Installation
9/16
EN