Drazice OKC 125 NTR Operation And Installation Manual - Page 5

Browse online or download pdf Operation And Installation Manual for Boiler Drazice OKC 125 NTR. Drazice OKC 125 NTR 20 pages. Tank-type water heaters for vertical mounting
Also for Drazice OKC 125 NTR: Operation And Installation Manual (17 pages), Operation And Installation Manual (12 pages), Operation And Installation Manual (20 pages), Operation And Installation Manual (18 pages), Operating And Installation Manual (20 pages), Operation And Installation Manual (18 pages)

Drazice OKC 125 NTR Operation And Installation Manual

1.2.3 EMERGENCY POWER CONSUMPTION

If no heated water is taken from the tank, a small amount of heat leaks. This loss is
measured for a period of 24 hours at the temperature of 65°C in the heater, and at 20°C in
its ambient area. The resulting value is expressed in [kWh/24h] and indicates the amount
of power needed to maintain the set temperature. Data Sheet pursuant to Directive No -
see Table 1.
ENERGY
HEAT TYPES
EFFICIENCY
CLASS
OKC 80
OKC 100; OKC
2
100/1 m
OKC 125; OKC
2
125/1 m
OKC 160; OKC
2
160/1 m
OKC 180; OKC
2
180/1 m
OKC 200; OKC
2
200/1 m
OKCE 50
OKCE 80
OKCE 100
OKCE 125
OKCE 160
OKCE 180
OKCE 200
Table 1
HEAT
NOMINAL
LOSSES
CAPACITY
Wh/24 hr/l
(l)
75
95
120
147
175
195
51
80
100
125
152
180
200
ELECTRICITY
CONSUMPTION
TIME OF
FOR HEATING
CONTENT
OF THE
HEATING
CONTENTS
(hours)
FROM 15°C TO
65°C IN kWh
2.5
4.8
3
6
3.8
8
5
9.6
5
10.6
5.5
12
1.5
3
2.5
4.8
3
6
3.8
8
5
9.5
5
10.6
5.5
12
HEAT
LOSSES
kWh/24 hr
- 5 -