Also for Drazice OKC 160 NTR / BP: Operation And Installation Manual (17 pages), Operation And Installation Manual (12 pages), Operation And Installation Manual (20 pages), Operation And Installation Manual (20 pages), Operation And Installation Manual (18 pages), Operating And Installation Manual (20 pages), Operating And Installation Manual (13 pages)

Drazice OKC 160 NTR / BP Operation And Installation Manual
EMERGENCY POWER CONSUMPTION
If no heated water is taken from the tank, a small amount of heat leaks. This loss is
measured for a period of 24 hours at the temperature of 65°C in the heater, and at 20°C in
its ambient area. The resulting value is expressed in units [kWh/24h] and indicates the
amount of power needed to maintain the set temperature.
NOMINAL CAPACITY
HEATER TYPE
OKC 80
OKC 100;
2
OKC 100/1 m
OKC 125;
2
OKC 125/1 m
OKC 160;
2
OKC 160/1 m
OKC 180;
2
OKC 180/1 m
OKC 200;
2
OKC 200/1 m
Table 1

1.3 DESIGN AND GENERAL HEATER DIMENSIONS

The heater tank is made of a steel plate and tested by 0.9 MPa overpressure. The inside of the tank is
enamelled. A flange is welded onto the bottom of the tank with a flange lid screwed to it.
A sealing ring is inserted between the flange lid and the flange. Thermo wells for placing a heating element
and sensors of regulation thermostat and safety fuse are located in the flange lid. An anode rod is mounted
onto the M8 nut. The water reservoir is insulated by means of polyurethane foam. Electric wiring is placed
underneath the plastic removable cover. The temperature of water can be set using the thermostat. In
combined versions, a heat exchanger is welded in the pressure tank. The heat exchanger is only intended
for the heating circuit.
TIME OF CONTENT HEATING
(L)
75
95
120
147
175
195
HEATING THE VOLUME
(HOURS)
FROM 15°C TO 65°C IN
2,5
3
3,8
5
5
5,5
ELECTRICICTY
CONSUMPTION FOR
kWh
4,8
6
8
9,6
10,6
12