1.3 TECHNICAL DATA

1.3.1 TECHNICAL DATA FOR TANKS
MODEL
CAPACITY
HEIGHT
DIAMETER
WEIGHT WITHOUT WATER
HOT WATER OPERATING PRESSURE
HEATING WATER OPERATING PRESSURE
MAX TEMPERATURE OF HEATING WATER
MAX TEMPERATURE OF HOT WATER
LOWER EXCHANGER HEAT DELIVERY
SURFACE
UPPER EXCHANGER HEAT DELIVERY
SURFACE
LOWER EXCHANGER CAPACITY
UPPER EXCHANGER CAPACITY
BOTTOM/TOP EXCHANGER OUTPUT AT
TEMPERATURE DROP 80/60 °C
HSW* HEATING TIME BY EXCHANGER
(LOWER/UPPER)AT HEAT DROP 80/60 °C
[MIN]
STATIC LOSS
*HSW - Hot sanitary water 45 ℃
Table 1
OKC 200
NTRR/SOL
l
200
mm
1377
mm
584
kg
104
MPa
1
MPa
1
°C
110
°C
90
m
2
0.8
m
2
0.8
l
5.5
l
5.5
kW
19/19
min
34/23
W
82
OKC 250
OKC 300
NTRR/SOL
NTRR/SOL
242
275
1557
1791
584
600
109
111
1
1
110
110
90
90
1
1.2
0.8
0.8
7
8.5
5.5
5.5
24/19
29/19
33/26
33/25
87
85