Drazice LX 35 Operating And Installation Manual - Page 9
Browse online or download pdf Operating And Installation Manual for Air Conditioner Drazice LX 35. Drazice LX 35 19 pages. Solar hybrid air-conditioning unit
The polarity of direct current wires (+) and (-) must be correct. The positive wire in the
outdoor air-conditioning unit is always red and marked with (+).
Connecting DC cable
(+) from photovoltaics
Photovoltaic panels must always be connected in series only:
Number of photovoltaic panels on a panel with power of 250W - 285W/panel: min 4 – max 8 panels
Number of photovoltaic panels on a panel with power of 300W - 350W/panel: min 3 – max 7 panels
- 9 -