Commodity Axis ViaAqua EF-4000 UVC Manual - Page 7

Browse online or download pdf Manual for Pond Pumps Commodity Axis ViaAqua EF-4000 UVC. Commodity Axis ViaAqua EF-4000 UVC 16 pages. Pressure pond filter
Also for Commodity Axis ViaAqua EF-4000 UVC: Instructions Manual (8 pages)

CONNECTION
Requires either 1.25" ID or 1.5" ID tubing. It is important to choose the largest
diameter ID tubing possible. Tubing and hose clamps are not included.
1. Connect the barbed fitting to the filter's intake and output.
2. Contact Tubing to the Pressure Pond Filter:
• Inlet: Connect tubing from the ViaAqua
intake of the filter. Then secure with a hose clamp.
• Outlet: Connect tubing from the filter back to the pump or water
features. For maximum circulation, place the output and water
pump as far a part as possible. It is not recommended to place them
next to one another.
3. Turn the flow control knob pointing to the intake port.
4. Drain: Remove cap.
5. Connect barbed fitting with a piece of tubing secure with a hose clamp.
6. To activate backwash turn off the pond pump and swith the flow control
knob so that the arrow points to the backwash/drain discharge port. Turn
the pond pump back on. Drain the water into a sewage system or garden.
®
4
5
5
pond pump to the barbed
backwash port
Sewage System
Pond Pump
Point knob
to the
or Garden
6