Anchorlift Barracuda 600 User Manual And Installation Manual - Page 7

Browse online or download pdf User Manual And Installation Manual for Boating Equipment Anchorlift Barracuda 600. Anchorlift Barracuda 600 16 pages. World class windlass system

Anchorlift Barracuda 600 User Manual And Installation Manual
WIRING DATA:
ELECTRICAL: See the appropriate wiring diagram for the correct electrical installation of your windlass model.
WARNING!
Always use a circuit breaker to protect the windlass motor and electrical cables.

Cable sizes

We recommend the use of the following cables, switch-wiring and circuit breaker sizes:
Windlass
Barracuda 600
Barracuda 900
Dolphin 1000
Mako 1500 12v
Mako 1500 24v
Aquarius 2500 24v
Aquarius 3000 24v
Note:
A) Cable and terminals should be suitable sizes.
B) Windlass performance is directly related to cable size and length.
C) Voltage drop over the wiring run must not exceed 2 volts.
TM
Cable length: 0-8m 0-24ft
16mm2
4-6AWG
25mm2
4AWG
25mm2
4AWG
35mm2
2AWG
25mm2
2AWG
35mm2
2AWG
35-50mm2
2-0AWG
over 8m 24ft
25mm2
4AWG
35mm2
4AWG
35mm2
2AWG
50mm2
2AWG
35mm2
2AWG
50mm2
0AWG
50mm2
0AWG
Installation
Circuit Breaker
80amp (90080)
100amp (90100)
100amp (90100)
135amp (90135)
80-100amp (90080-90100)
135amp (90135)
175amp (90175)
www.anchorlift.com
5