ATI Audio DDA-106 SERIES 2 Operating And Maintenance Manual - Page 6

Browse online or download pdf Operating And Maintenance Manual for Amplifier ATI Audio DDA-106 SERIES 2. ATI Audio DDA-106 SERIES 2 7 pages. 192khz aes/ebu digital audio distribution amplifiers

ATI Audio DDA-106 SERIES 2 Operating And Maintenance Manual

SPECIFICATIONS

INPUTS
Connectors:
Level:
Impedance:
Termination:
Cable Length:
Equalizer:
Sample Rates:
Clock:
OUTPUTS
Connectors:
Levels:
Impedances:
Output Jitter:
Propagation Delay: <25 nanoseconds
POWER
SIZE
WEIGHT
MODELS:
ATI Audio Inc.
■ Tel: 856-626-3480
XLR female or BNC, DC isolated from chassis.
Input connector pairs paralleled for loop-thru.
200mVp-p minimum
Transformer isolated, balanced and floating, XLR inputs 110
ohms, and BNC inputs 75 ohms
Terminating resistors may be switched in or out from front
panel
300m of 110-ohm cable, 1000 m of 75 ohm coax (with
equalizer)
Automatic via front panel actuation button, independent for
Inputs 1 or Input 2
Accepts 27kHz to >192kHz
With re-clocking on, regenerated from input signal; clock
jitter <300 picoseconds peak-to-peak at 96kHz sample rate
With re-clocking off, input clock is passed directly to outputs
6 x XLR male or 6 x BNC chassis mount
XLR, 4Vp-p loaded at 110 ohms
BNC, 2Vp-p loaded at 75 ohms
XLR: 110 ohms, balanced, transformer isolated
BNC: 75 ohms, unbalanced
<300 picoseconds peak to peak at 96kHz sample rate
Internal supply, 115/230VAC+/-10%, 50/60Hz, 10VA,
IEC320 3 pin connector
1 RU, 19"(48.3cm) W X 1.75"(4.5cm) H X 8.5"(21.6cm) D
7 lbs (3.2kg) net; 9 lbs (4.1kg) shipping weight
DDA-106XLR
DDA-106BNC
Fax: 856-504-0220
www.
audio.com