ATI Audio DDA416 Operating And Maintenance Manual - Page 12

Browse online or download pdf Operating And Maintenance Manual for Amplifier ATI Audio DDA416. ATI Audio DDA416 14 pages. Quad 1x4 aes/ebu distribution amplifier and 1x6 clock distribution amplifier

ATI Audio DDA416 Operating And Maintenance Manual
 
 

INSTALLATION

 
LOCATION
 
The DDA is readily installed into a 2 RU, 19" rack. The DDA is only to be installed in an inside
location where it is protected from inclement weather. Operate the DDA in temperature range of +5
to +40°C (105°F), with relative humidity ranging from 5 to 85%.
 
 
 
POWER
 
Connector for socket fused IEC 320/C13. Power cord is supplied. The DDA has a rear panel On
Off power switch.
 
POWER INPUT SPECIFICATIONS:
 
Voltage .......................................................................................85 ~ 264Vac
Frequency .....................................................................................47 to 63Hz
 
This equipment is connected to earth through the center conductor of the AC mains cable. Proper
grounding protects user/operators from electric shock, and it must be maintained whenever the unit
is connected to AC.
 
 
 
WIRING
 
XLR inputs for external clock sources require special controlled impedance, 110 ohm, low loss, foil
shielded, twisted pair cables. Standard audio cable is not recommended. Belden and most other
cable manufacturers offer special digital audio cabling for this application. BNC connectors use 75-
ohm coax (RG59). Select a cable for losses less than 20dB at 12MHz (for data rates up to 96 k
samples) at the maximum distance you require. Keep cable length as short as possible
 
DDA-­‐416/WC106   M anual  
12