Carmanah Go Power! GP-HS1500 Owner's Manual - Page 14
Browse online or download pdf Owner's Manual for Inverter Carmanah Go Power! GP-HS1500. Carmanah Go Power! GP-HS1500 16 pages. Pure sine wave inverter
![Carmanah Go Power! GP-HS1500 Owner's Manual](/uploads/products/server2/1412566/1412566.jpg)
___________________________________________________________
•
Keep the cables between the battery and the power inverter as short as
possible and twist them together with about two to three twists per foot. This
minimizes radiated interference from the cables.
7.2 Troubleshooting Guide
Problem and
Symptoms
No output voltage,
no voltage
indication.
No output voltage,
Over Voltage
indicator on
Low battery alarm
on all the time.
No output voltage
and Under Voltage
indicator on
No output voltage,
Over Temp
indicator on, load
in excess of:
1500 W:
150 A (12V) or 75
A (24 V)
No output voltage,
Over Temp
indicator on, load
less than:
1500 W:
150 A (12 V) or 75
A (24 V)
No output voltage,
Over Load
indicator on.
Possible
Solution
Cause
Inverter
Turn inverter ON. Check wiring to inverter.
switched off.
No power to
inverter
Internal fuse
Have qualified service technician check and
open
replace.
Reverse DC
Have qualified service technician check and
polarity
replace fuse, OBSERVE CORRECT
POLARITY.
High input
Make sure that inverter is connected to 12 V
voltage
or 24 V battery. Check regulation of
charging system.
Poor DC
Use proper cable and make solid
connections. Use new battery. Reduce load.
wiring, poor
battery
condition.
Low input
Recharge battery, check connections and
voltage
cable.
Thermal
Allow inverter to cool off. Reduce load if
shutdown
continuous operation required.
Thermal
Improve ventilation, make sure ventilation
shutdown
openings in inverter are not obstructed, and
reduce ambient temperature.
Short circuit
Check AC wiring for short circuit or improper
or wiring
polarity (hot and neutral reversed).
error.
GP-HS1500
14