Andea Electronics TPAD10M User Manual - Page 12

Browse online or download pdf User Manual for Scanner Andea Electronics TPAD10M. Andea Electronics TPAD10M 19 pages. Rfid pad reader

Andea Electronics TPAD10M User Manual
2)Timing for Auto Close RF:Value range: 0-256, the RF enters the idle mode if
no operation in a specified time.
Air protocol selection
1) ISO15693: Enable to count tags of ISO15693 air protocol.
2) ISO14443A: Enable to count tags of ISO14443A air protocol.
3) ISO18000p3m3: Enable to count tags of ISO18000p3m3 air protocol.
4) ISO14443B: Enable to count tags of ISO14443B air protocol.
ISO15693
1) Data coding: 1/4, 1/256.
2) Subcarrier: single negative carrier, double negative carrier.
3) ASK 10%: ASK modulation depth setting takes effect after the button is ticked.
Otherwise, it is ASK 100%.
4) ASK modulation depth: 0.5% -60%
ISO18000p3m3
1)M: Manchester 2,Manchester 4
2) DR:FC/16847khz, FC/32424khz
3) Modulation depth:0.5%-29%

5.1.4. Inventory Parameters

Figure 13 Configuration interface for inventory parameters
Guangzhou Andea Electronics Technology Co., Ltd.
http://www.gzandea.com
User manual
10/16