SPECIFICATIONS
OUTPUT CLIPPING LEVEL
DISTORTION
FREQUENCY RESPONSE
OUTPUT NOISE
IMPEDANCE FULL GAIN
HUM REJECTION
INPUT IMPEDANCE
GAIN
OUTPUT ISOLATION
POWER
SIZE
MOUNTING
Day Sequerra │ 154 Cooper Rd. #902 │ W. Berlin, NJ 08091 │ Voice 856-719-9900 │ [email protected] │ www.atiaudio.com
@ 24dBm output and input levels to
+24dBm
+24dBm / 600 ohms
.2% maximum THD, 20Hz to 20kHz
+/- .25dB, 20 to 20000 Hz.
-3dB at 100 kHz
-70dBm maximum
20kHz measurement bandwidth
600-ohm source
80dB for common mode hum
Balanced differential inputs, 30,000
ohms bridging +24dBm maximum input
level.
26dB, front panel adjustable
70dB minimum at 1 kHz, any output to
any other output. Unit will tolerate up to
two shorted outputs with no reduction in
headroom.
115 / 230 VAC +1- 10%, 47-63 Hz.
8-1/2" W x 1-3/4" H x 7" D, 2-1/2 lbs.
Suction feet for non-slip desk mounting
Rack mount system 21075-501 mounts
two units in one rack.