ATI Technologies DA1000 Operating And Maintenance Manual - Page 6

Browse online or download pdf Operating And Maintenance Manual for Amplifier ATI Technologies DA1000. ATI Technologies DA1000 6 pages. Ati distribution amplifier operating and maintenance manual

ATI Technologies DA1000 Operating And Maintenance Manual

SPECIFICATIONS

OUTPUT CLIPPING LEVEL
DISTORTION
FREQUENCY RESPONSE
OUTPUT NOISE
IMPEDANCE FULL GAIN
HUM REJECTION
INPUT IMPEDANCE
GAIN
OUTPUT ISOLATION
POWER
SIZE
MOUNTING
Day Sequerra │ 154 Cooper Rd. #902 │ W. Berlin, NJ 08091 │ Voice 856-719-9900 │ [email protected] │ www.atiaudio.com
@ 24dBm output and input levels to
+24dBm
+24dBm / 600 ohms
.2% maximum THD, 20Hz to 20kHz
+/- .25dB, 20 to 20000 Hz.
-3dB at 100 kHz
-70dBm maximum
20kHz measurement bandwidth
600-ohm source
80dB for common mode hum
Balanced differential inputs, 30,000
ohms bridging +24dBm maximum input
level.
26dB, front panel adjustable
70dB minimum at 1 kHz, any output to
any other output. Unit will tolerate up to
two shorted outputs with no reduction in
headroom.
115 / 230 VAC +1- 10%, 47-63 Hz.
8-1/2" W x 1-3/4" H x 7" D, 2-1/2 lbs.
Suction feet for non-slip desk mounting
Rack mount system 21075-501 mounts
two units in one rack.