13. Outline size
13-3
AJR3- 1
090 to
AJR3-1
200
13-3
AJR3- 1
250 to
AJR3-1
500
In case that the outline size is changed, please refer to the real object.
-23-
14. Application range
14-1 Sort of application load
ANDLI AJR3-1000 soft starter can meet the requirement that drives heavy loads, the below table
is only for reference.
Starting ramp
Stop ramp
Applicable loads
time (s)
time (s)
Centrifugal pump
16
20
Ball mill
20
6
Fan
26
4
Light load motor
16
2
Piston type
16
4
compressor
Elevating
6
10
machinery
Agitator
16
2
Crusher
16
10
Spiral type com
2
16
pressor
Spiral type belt
20
10
conveyer
Conveyer belt
20
10
Heat pump
16
20
15. RS485 communication
The ANDELI AJR3-1000 soft starter can be connected with personal computer and plc through
build-in rs485 standard interface., it can proceed serial communication.
we can use the host command to start/stop the soft starter, it also can monitor its running state and
modify its function data etc..
please refer to the rs-485 operating manual about the detail communication content.
we can use rs485 communication of soft starter through a computer to proceed remote control,
order input, running state control and input the function data of many soft starters in one time.
main functions
input the stop order
monitor the running state
real-time trace (display the running information in a table)
read and write in the function code in one time, and keep it in the document.
please contact with us to negotiate the communication software.
Voltage starting
Initial voltage
Current-
(Max current-
(%)
limit starting
limit value)
40
4
2.5
60
4
3.5
30
4
3.5
30
4
3
40
4
3
60
4
3.5
4
3
50
4
50
3.5
40
4
3
2
40
4
40
4
2.5
40
4
3
-24-