Anden A65 Installation Instructions Manual - Page 2
Browse online or download pdf Installation Instructions Manual for Controller Anden A65. Anden A65 7 pages. Humidifier control
TABLE OF CONTENTS
SAFETY INSTRUCTIONS � � � � � � � � � � � � � � � � � � �1
OVERVIEW � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
SPECIFICATIONS � � � � � � � � � � � � � � � � � � � � � � � � � 2
MATERIALS PROVIDED � � � � � � � � � � � � � � � � � � � 3
LOCATION RECOMMENDATIONS � � � � � � � � � � 3
Mount Control� � � � � � � � � � � � � � � � � � � � � � � � � � 4
Wiring� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 6
OVERVIEW
The Anden® Model A65 Humidifier Control provides control of the humidifier from the grow
space� The control allows for adjustment of the humidity setting and to turn the humidifier on and
off from a convenient location� The Model A65 uses an onboard sensor to monitor the relative
humidity in the space in which it is located and displays the measured relative humidity on the
digital display�
SPECIFICATIONS
ELECTRICAL
Voltage: 24V AC +/-20%
Input Voltage and Current
Current: 25mA (nominal), 50mA (max�) at 24V AC
Output
Dry Contact, Normally Open - H Terminals
CONTROL
Humidity Setting Range
10% - 90% RH
Accuracy
+/-5% RH
Differential
3%
Low Temp
40°F
High Temp
99°F
2
Power Up� � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 8
Test Mode � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
Humidity Setting � � � � � � � � � � � � � � � � � � � � � � � 9
Offset � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 9
Turning On and Setting the Control� � � � � � 10
Sequence of Operation� � � � � � � � � � � � � � � � � 10
Error Codes � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
Troubleshooting Guide � � � � � � � � � � � � � � � � � � 11
MATERIALS PROVIDED
MATERIALS PROVIDED
• Wall-Mount Control
• Mounting Screws
• Drywall Anchors
LOCATION RECOMMENDATIONS
MOUNT CONTROL
• In an area where moisture levels need
to be monitored and controlled�
• On an interior wall�
• At or near canopy height�
• At least 18" from an outside wall�
FIGURE 1 - MOUNTING LOCATION
NO
MATERIALS NOT PROVIDED
• Wires
• Wire Nuts
DO NOT MOUNT CONTROL
• In the flow of a supply register.
• Behind doors, in corners or other dead air spaces�
• In direct sunlight, near lighting fixtures, or other
appliances that give off heat�
• On an outside or unconditioned area wall�
• In stairwells or near outside doors�
• On a wall with concealed pipes or ductwork�
18"
MINIMUM
AT OR NEAR
CANOPY HEIGHT
NO
90-2545
3