ANDERBERG KLIMA HP50 Instruction Manual - Page 5
Browse online or download pdf Instruction Manual for Dehumidifier ANDERBERG KLIMA HP50. ANDERBERG KLIMA HP50 12 pages.
1) On/off switch
Puts the device into the standby mode and turns it
back on.
2) LED „ON"
The LED „ON" lights up, when the device is supplied
with electrical power.
3) Control for relative humidity
Using the buttons „+ % RH" and „– % RH" you can
preset the desired level of relative humidity.
Upon pressing either of these buttons the display
switches from showing the actual value to showing
the set value. Shortly after the desired value has been
set, the display switches back to the current value.
You can adjust the desired value between 31-90 % rel.
humidity. Once this value has been reached the
device automatically switches off.
The dehumidifier switches on when the set value has
been exceeded by +1 and switches off when the value
falls below the set value by -2. The minimum running
and pause times of the compressor is 1 minute each.
When you preset a level of 30% relative humidity the
device will run in continuous operation and will not
switch off even when this value has been reached.
4) Fan speed selector
The DEHUMID HP 50 can run with two different fan
speed stages.
When you change the setting the display will show the
selected fan speed stage. After a short period of time
it switches back to showing the current humidity
value.
8. Operation
1
2
3
,
4
5
6
Stage 1:
High performance
The fan is running at maximum speed.
We recommend this setting when you
desire
dehumidification.
Stage 2:
Low performance
The fan is running at reduced speed
and
therefore
However,
performance is also being reduced.
5) LED „water tank full"
When the LED „FULL" lights up the water tanks are
either full or not inserted properly. The device then
switches off automatically.
Empty the water tanks (see 13.) and make sure to
correctly put them back into the dehumidifier. After a
short period of time the device will then resume
operation.
When removing the water tanks during operation the
device will sound a bleep and stops running.
When the LED „FULL" flashes, the device is set to
operate with direct drain.
6) Display
By default the display shows the current actual
humidity level.
When changing the fan stage it shows the selected
stage.
When changing the desired humidity value the display
shows that value.
If there is an error regarding the radio signals it shows
„Code 05".
When the device has been cut off from the mains the
display will show the current software version upon
first activation.
After a short period of time the display always
switches back to the current humidity level.
a
high
and
especially
silently.
the
dehumidification
rapid