• the drain pipe is able to withstand temperatures of at least
100℃.
• there are no constrictions in hoses or elbows in metal pipes,
along the entire drain path.
• horizontal sections where water can collect and stagnate
(minimum slope 5%) are avoided.
E.6
Electrical connection
E.6.1
Electrical connection
IMPORTANT
The connection to the electrical power supply must
be in compliance with the current national and local
regulations.
Before connecting, make sure the voltage and frequency
match that given on the dataplate.
• Connect the appliance to the power supply in a permanent
way with an H07 RN-F type cable.
• Install the power cable in a metal or rigid plastic pipe without
any sharp parts.
• Install ahead of the appliance an omnipolar switch of
suitable capacity with contact opening distance of at least
3 mm.
Install the switch in the building's electrical system, in the
immediate vicinity of the appliance.
• Appliance max. leakage current is 5 mA.
• Install ahead of the appliance a device (interlocked plug,
lockable switch or similar devices) lockable in the open
position during maintenance.
• Connect the appliance to an efficient earthing system.
For that purpose, the connection terminal block has a
terminal with the symbol
• Include also the appliance into an equipotential system. The
equipotential wire must have a section of at least 10 mm
This connection is made with the setscrew marked
located externally near the power cable entry.
IMPORTANT
Only for 400V 3~ models
This appliance can be connected only to a supply
with maximum system impedance no more than:
6 GN 1/1 and 10 GN 1/1 = 0.18 Ω
6 GN 2/1 and 20 GN 1/1 = 0.043 Ω
10 GN 2/1 = 0.033 Ω
In case necessary, please consult your supply
authority for system impedance information.
CAUTION
If the supply cord is damaged, it must be
replaced by the manufacturer, its service
agent or similarly qualified persons in
order to avoid a hazard.
IMPORTANT
The manufacturer declines any liability if the current
national and local regulations and possible safety
regulations are not respected.
E.6.2
Power cable installation in electric models
To connect the power cable to the appliance, proceed as
follows:
1. Remove the left side panel of the oven;
2. If applicable in your model undo the screw fixing the
external box under the oven;
3.
Loose the ring to let the power cable run through the
cable clamp;
6 - 10 grids models
Cable clamp type for 220-240 V 3~
for connecting the earth wire.
Cable clamp type for 380-415 V 3N~ or 3~, 400-430 V 3N~,
440 V 3~ and 480 V 3~
20 grids models
2
.
,
4.
Unsheathe all wires from the cable;
5.
Run the wires toward the terminal block;
29