Browse online or download pdf Operating And Maintenance Instructions Manual for Freezer Electrolux AOFP202RU4. Electrolux AOFP202RU4 27 pages. Bcf 30kg 6 gn1/1 lw (240/3/60hz), bcf 50kg 10 gn1/1 lw (240/3/60hz) / bcf 100kg 20 gn1/1 lw (240/3/60hz) / bcf 70kg 10 gn2/1 lw (240/3/60hz) / bcf 180kg 20 gn2/1 lw (240/3/60hz) / bcf 30kg 6 gn1/1 lw (208/3/60hz) / bcf 50kg 10 gn1/1 lw (208/3/60hz) / bcf
C.4.1.2.2 Service alarms requiring service center assistance
When the alarms listed below occur, call the service center for
assistance.
SYMBOL
DESCRIPTION
Minimum cell temperature
E1
E2
Minimum evaporator temperature
E3
Cell probe malfunctioning or disconnected
Evaporator probe malfunctioning or disconnected
E4
E5
Ambient probe malfunctioning or disconnected
Condenser probe malfunctioning or disconnected
E6
Core probe 1 malfunctioning or disconnected
E7
Core probe 2 malfunctioning or disconnected
E8
E9
Core probe 3 malfunctioning or disconnected
Pressure switch tripped
E10
Compressor overload
E11
E12
Evaporator fan fault
E13
Internal clock malfunction
All alarms will be stored as follows: the "TEMPERATURE"
display shows the alarm number, e.g. "AL 1", "AL 2", etc.,
whereas the "TIME" display shows the ALARM CODE, e.g. "E1",
"b1", etc...
If no alarm is active: the first alarm, i.e. the last to occur, is
displayed.
Use the
buttons to scroll the stored alarms.
After displaying the last alarm, the
on the display and after 12 seconds the unit will automatically
go back to the main menu.
When the next alarm occurs, the current ones will be cancelled
(automatic reset).
If an alarm is active, going into the utility will silence the buzzer
and simultaneously access the alarm message display.
Use the
buttons to scroll the stored alarms.
After displaying the last alarm, the l
appear on the display and after 5 seconds the unit will
automatically go back to the main menu.
The function for cancelling from the memory is disabled when
there are alarms active (i.e. the reset is disabled).
To cancel the alarms, press
seconds.
ATTENTION: The reset function is disabled if the operator did not
see the stored alarms. When the reset function is enabled the
message "RES" appears on the TEMPERATURE display.
ACTION
"——"
message will appear
"——"
message will
+
together for 5
C.5 HACCP CONNECTIONS
(ACCESSORIES)
Refer to the handbook enclosed with the kit for instructions
on installing the accessories.
The board has a serial communication line for interacting with
other units, printers or a HACCP control station in a network.
This can be connected in the following ways:
• directly to a device that communicates in TTL (e.g. the FT190ELX
printer), by setting the parameter E485="Prn"
• to an RS485 communications network, by setting the parameters
E485="PC" and PRTY="1" (refer to the handbook supplied with
the kit) inserting the conversion card RS485-LK-P and
Adr="Network address".
D.1 ROUTINE MAINTENANCE
D.1.1 PRECAUTIONS FOR MAINTENANCE
Routine maintenance tasks can be performed by non-
specialised personnel. When performing maintenance please
follow the instructions closely, keeping safe at all time. The
manufacturer declines any responsibility for injury sustained
from unsafe acts.
ATTENTION:
do not touch the appliance if hands and/or feet are wet. Before
screwdrivers and sharp objects on the cooling circuit.
D.1.2 CLEANING THE CABINET AND ACCESSORIES
It is advisable to clean the chamber every week; increasing this
frequency according to appliance use.
Before using the unit, clean all the internal parts and accessories
with warm water and either neutral soap or products
that are over 90% biodegradable (in order to redu-
ce the emission of pollutants into
the environment), then rinse and dry
thoroughly. Do not use solvent-
based detergents (e.g. trichloro-
ethylene) or abrasive powders for
cleaning. Coat the metal panels with
vaseline oil.
The trolleys must be cleaned with high pressure
water jets.
Drain off the water used in the process of cleaning by removing
the drain plug at the bottom center of the chamber, so that the
liquid flows out into the drain tray under the cabinet. This tray
must be emptied periodically (AOFP061U4-061U, AOFP101U4-
101U, AOFP102U4-102U models).
Refit the drain plug immediately after the cleaning.
Note: make sure the drain tray has been emptied before
removing the drain plug.
21
performing any cleaning or
maintenance disconnect the
appliance from the electrical
source and carefully unplug the
appliance. It is DANGEROUS AND
UNADVISEABLE to remove the
safety guards, AND IS NOT
REQUIRED
for
maintenance. Wear protective
gloves
when
cleaning
condenser. Do not use scissors,
routine
the