1- Exhaust
airoutlet onthe rear o fthe
appliance
(standard)
2- Exhaust
airoutlet ontheside (optional)
3- Exhaust
airoutlet ontheunderside
ofthe
appliance
(optional)
Specialexhaustairconnections
mustbeobtainedfromyourdealer
or partsupplier f or either
connection type (seepage11).
Sideexhaustkit
Bottomexhaustkit
A qualified technicianshould
changethe exhaustair outletto
the optionalconnectionlocation.
Ductwork
Toensureoptimumperformance,
the ductingsystemof the dryer
shouldbeas shortas possiblewith
a minimum numberof elbows.Your
dryerwillworkbestwhenthe
ventingsystemhasas few airflow
restrictions as possible. E xhaust
ductingwhichis longerthan
recommended mayextenddrying
time,causetintto accumulate and
affectdryerperformance anddryer
lifetime.
Fourinch(approx.100ram)
diameterductingshouldbe used.
Useeitherrigidmetalor flexible
metalductingmaterial.
DONOTuseplasticor non metal
duct withthis dryer.
DONOTassemble the ductwork
withscrewsor fasteners that
extendintothe duct.Theywillserve
as anaccumulation pointfor tint.
Jointsshouldbe secured with duct
tape.
/
All joints should be tight to avoid
leaks. The mate end of each duct
section must point away from the
dryer.
Whether connecting
to an existing
venting system or a new venting
system, make sure that all ducting
is clean and free of tint.
The maximum
permitted
length for
both rigid and flexible metal duct is
shown in the table below.
Numberof
RigidDuct
Flexible Duct
90°Turns
or EJbows
0
66 ft,
45 ft,
(2011 cm)
(I 372 cm)
1
56 ft.
36 ft,
(1707 cm)
(1097cm)
2
48 ft,
29 ft,
(1463 cm)
(884cm)
3
39 ft,
22 ft.
(1189 cm)
(671cm)
4
30ft,
16ft,
(914 cm)
(488cm)
Note:
Side and bottom
exhaust
installations
have a 90 ° turn inside
the dryer. To determine
maximum
exhaust length, add one 90 ° turn to
the chart.
More than two 90 ° turns are not
recommended.
For best
performance,
separate all turns by
at least 4 ft. of straight duct,
including
distance
between
last turn
and exhaust
hood.
Good
Better
Exhaust
vent hood
The exhaust
duct must end with an
approved
exhaust vent hood with
swing out damper(s).
DO NOT use
an exhaust vent hood with
magnetic
tatches.
To avoid exhaust restriction,
the
outlet must be a minimum
of
12 inches (30 cm) above ground
tevel or any other obstructing
surface.
Required
parts
The parts required for the exhaust
air system (elbows, lines, exhaust
air outlets) are not included
in
standard
detivery of the dryer.
10