5. Burner maintenance
5.1 Troubleshooting and troubleshooting
– Flame touches burner block or furnace refractory
Burner repositioning
– Thick smoke or oil mist during combustion
Venturi blocked
Amount of atomizing air not enough
High viscosity and low preheating temperature
– The flame is short and ring-shaped
Burner repositioning
– Flame length is too long
Reduce oil flow or increase atomizing air
– Flame length is too short
Increase oil flow or reduce atomized air
Note:
In any of the above cases, the oil nozzle or high-pressure plate may be blocked.
In this case, the burner must be removed and cleaned.
5.2 Inspectionn of the nozzles
The burner should be inspected regularly. This is especially important after a
prolonged period of shut-down.
During the first month of operation of the burner, inspection of the nozzle must be
carried out every week. During the second month, the period between inspections
can be extended to two weeks. Anderson recommends that each nozzle is inspected
at least once every month. Every time a burner is left in the furnace
6. Spare parts
With proper use and regular servicing of the burner, we recommend the following
parts:
–
Quick Coupler high temperature gasket
–
Outer nozzle gasket
–
Spare burner nozzle
Attention:Safety audit is prohibited when burner is running, otherwise,
accident could be caused!
If you have any question. Please call us or send e–mail to get more information
Our telephone no. is +86 (512) 6592 4663