9
Wiring diagram
Electrical connection with 4-PIN M12 plug connection, option "M"
Anderson Negele
4-PIN Cordset "M"
1: Brown
2: White
3: Blue
4: Black
Electrical connection with 5-PIN M12 plug connection, option "L"
Anderson-Negele
5-PIN Cordset "L"
1: Red
2: Black
3: Green
4: n.c.
5: White
Electrical connection with cable gland
10
Repair and maintenance
The level sensor described here is maintenance-free and contains components that could be repaired.
+ Supply voltage
+ Output 4...20 mA
- Output
- Supply voltage
Standard
Description
5-PIN Cordsets
1: Brown
+ Supply voltage
2: White
- Supply voltage
3: Blue
- Output
4: n.c.
5: Grey
+ Output 4...20 mA
18