The water resistant CYPRES in use
Replace FILTER after each contact with liquids
Replace SEAL after each opening of housing
Water resistant for 15 minutes at a water depth of up to 15ft / 5m.
•
•
After a cuttter has been in contact with salt water, the cutter should
be rinsed briefly with fresh water.
•
Exchange the filter after each contact with water, but no later than
after 24 months.
•
Renew the sealing gasket after each opening of the housing, but no
later than after 24 months.
•
In order to exchange the filter the housing need NOT be opened.
Turn the filter out in anti-clockwise direction and insert the new filter
as described at point 3 of this instruction manual.
If you have a plug on your cutter cable (field replaceable cutter) and you
have to renew the cutter, please follow the instructions on the next page.
CYPRES
Water resistant for 15 min. at 15ft / 5 m.
or every 24 months, whatever comes first.
or every 24 months, whatever comes first.