Ativa 516-015 User Manual
Browse online or download pdf User Manual for Power Supply Ativa 516-015. Ativa 516-015 2 pages.
1
516-015
User Guide
User Guide
4
3
OPERATING ENVIRONMENT
o
o
32 - 104
F (0 - 40
C)
Computer
Monitor
STATUS INDICATORS, ALARMS and CIRCUIT BREAKER
There are four status indicators (lights) on the front panel of the UPS (On
Line, On Battery, Overload, and Replace Battery).
On Line
On Battery
Overload
Replace Battery
On Line (blue) - is lit whenever utility power is powering the Battery
Backup outlets.
On Battery (yellow) - is lit whenever the battery of the UPS is powering
equipment connected to the Battery Backup Outlets.
Overload (red) - is lit or flashing whenever power demand has exceeded
the capacity of the UPS.
Replace Battery (red) - is lit whenever the battery is near the end of its
useful life, or if the battery is not connected (see above). A battery that is
near the end of its useful life has insufficient run-time and should be
replaced.
2
CONTENTS
CONNECT BATTERY CARTRIDGE
RJ-11
RJ-11
RJ-45
RJ-45
USB
RJ-45
Coax
Coax
Æ
ATIVA
CONNECT EQUIPMENT / POWER
Fax
Printer or Scanner
External Disk or
CD / DVD Drive
To 120 VAC Wall Outlet
Four Beeps Every 30 Seconds - this alarm is sounded whenever the UPS is running
On Battery. Consider saving work in progress.
Continuous Beeping - this alarm is sounded whenever a low battery condition is
reached. Battery run-time is very low. Promptly save any work in progress, and exit
all open applications. Shut down the operating system, computer and the UPS.
Continuous Tone - this alarm is sounded whenever the Battery Backup outlets are
overloaded.
Chirps for 1 Minute Every 5 Hours - this alarm is sounded whenever the battery
has failed the automatic diagnostic test.
Circuit Breaker - the circuit breaker button located on the rear panel of the UPS will
stick out if an overload condition forces the UPS to disconnect itself from utility
power. If the button sticks out, disconnect non-essential equipment. Reset the circuit
breaker by pushing the button inward.
1
2
5
3
CHECK BUILDING WIRING
6
FAULT INDICATOR
If the rear panel Building Wiring Fault (red) indicator is lit,
a potential shock hazard exists due to one of the following
conditions:
• Open or high resistance ground
• Hot and Neutral polarities are reversed
• Overloaded neutral circuit
Improper building wiring should be corrected by a
RJ-45/
qualified electrician. Do not use the UPS until the
RJ-11
condition that caused the fault is corrected.
Note: Improper building wiring will not prevent the UPS
from operating, but it will limit its protection capability.
Phone
Jack
CABLE IN
CABLE OUT
Building Wiring Fault
Building
Indicator
Wiring
Fault
TRANSFER VOLTAGE and SENSITIVITY ADJUSTMENT
In situations where the UPS or connected equipment appears too sensitive to input voltage, it may be
necessary to adjust the transfer voltage. This is a simple task requiring use of the front panel push
button. To adjust the transfer voltage, proceed as follows:
1. Plug the UPS into the utility power source but do not turn the unit on. The UPS will be in Standby
Mode (no indicators lit).
2. Press and hold the front panel ON/OFF switch fully inward for 10 seconds, until all LED
indicators on the UPS flash to acknowledge it has entered Programming Mode. Release the ON/
OFF button, and the UPS's LEDs will flash per table below, indicating it's current sensitivity
setting.
Note: the UPS automatically exits programming mode in 5 seconds if no buttons are pressed.
3. Use the table below to decide which Sensitivity setting is desired.
Indicators
Sensitivity
Input Voltage
Flashing
Setting
Range
(for utility
operation)
1
Low
78 - 142 Vac
(yellow)
2
Medium
88 - 139 Vac
(yellow, and red)
(factory
default)
3
High
88 - 136 Vac
(yellow, red, and
red)
CONNECT MODEM/PHONE/FAX and
TVSS Ground
If needed, the UPS features a
TVSS ground screw for
connecting the ground lead of
any additional stand alone surge
suppression devices, such as an
From stand alone
ProtectNet product; or any
data line surge
RJ-45/
electronic device with an
suppressor or
external ground connection.
RJ-11
electronic device
RJ-45/
RJ-45/
RJ-11
RJ-11
Computer
Modem Port
OR
Phone or Fax
4. To select the Low Sensitivity setting, press and hold the ON/OFF switch
for 1-2 seconds (until a beep is heard). Upon release, the yellow indicator
will flash, indicating Low Sensitivity.
5. To select the Medium Sensitivity setting (the unit's default), press and
hold the ON/OFF switch for 1-2 seconds (until beep is heard). Upon
release, the yellow indicator will flash. Press and hold the ON/OFF
button again for 1-2 seconds (until beep is heard). Upon release, the
yellow and one red indicator will flash, indicating Medium Sensitivity.
6. To select the High Sensitivity setting, press and hold the ON/OFF switch
for 1-2 seconds (until beep is heard). Repeat this two more times. Upon
final release, the yellow and two red indicators (bottom three indicators)
will flash, indicating High Sensitivity.
Use When
7. The UPS will automatically exit Programming Mode in five seconds,
and is ready for use.
Input voltage is extremely low or
high. Not recommended for computer
loads.
UPS frequently goes On Battery.
Connected equipment is sensitive to
voltage fluctuations.
SWITCH ON THE UPS
7
Note: Allow the UPS to charge for a full or 24 hours prior
to use.
Press the front panel Power ON/OFF switch and observe
that the following events occur after pressing and
releasing the switch:
• The blue On Line indicator flashes.
• The yellow On Battery indicator lights while a Self-
Test is being performed.
• When Self-Test has successfully completed, only the
blue On Line indicator will be lit.
• If the internal battery cartridge is not connected (see
Step 2 above), the blue On Line indicator, and red
Replace Battery indicators will light. The UPS will
also emit a chirping sound.
ON LINE
ON BATTERY
OVERLOAD
REPLACE BATTERY
990-2491