Comnet Copper Line CLFE8EOU Installation And Operation Manual - Page 9
Browse online or download pdf Installation And Operation Manual for Extender Comnet Copper Line CLFE8EOU. Comnet Copper Line CLFE8EOU 12 pages. Ethernet over copper extender with pass-through poe to 15 watts
INSTALLATION AND OPERATION MANUAL
INSTALLATION INSTRUCTIONS
1 - SET 10/100 SWITCH
Locate the 10/100 data rate DIP switch on the unit.
Set the data rate according to bandwidth required. The default setting for the data rate DIP switch is 100Mbps.
NOTE: The data rate must be set the same on both the local and remote units.
2 - SET WIRE PAIR DIP SWITCHES (UTP MODELS ONLY, FOR COAX MODELS SKIP TO STEP 3)
Locate the wire pair DIP switch on the unit.
Set the pair according to number of twisted wire pairs used (1 or 4). The default setting for the wire pair DIP switch is 4 pair.
NOTE: The number of pairs selected must be set the same on both the local and remote units. PoE Pass-Through mode
is only available in 4-pair mode and requires a PD device connected to the ComNet remote unit to operate.
3 - SET LOCAL/REMOTE SWITCHES (1 AND 4 CHANNEL UNITS ONLY, FOR RACK UNITS SKIP TO STEP 4)
Locate the Local/Remote Dip switch and set to "LC" at the head end or "RM" at the camera end.
Locate the Local/Remote push button switch (coax units only), and set to the same setting as the dip switch.
The factory setting for these switches is "RM".
The CLFE8EO(C,U) and CLFE16EO(C,U) units are preconfigured as Local devices.
4 - CONNECT EXTENDED WIRING
Connect Extended Distance Port to field wiring.
5 - CONNECT NETWORK WIRING
Using CAT5/5e, connect Local unit to network and Remote unit to camera.
6 - CONNECT POWER
Connect power to unit per the following table:
Unit
CLFE1EO(C,U)
CLFE4EO(C,U)
CLFE8EO(C,U)
CLFE16EO(C,U)
Contact ComNet pre-sales support, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.
†
7 - VERIFY FUNCTIONALITY
See LED table below and Troubleshooting Guide if corrective action is needed. See figures beginning on page 6 for LED
configurations for each model.
PWR
GREEN
Power Applied
YELLOW
–
OFF
Power Off
Ethernet
Ethernet
Activity
Link
TECH SUPPORT: 1.888.678.9427
Table 1 – Power Connections per Use Case
Local Power
9 to 36 VDC or 18 to 32 VAC
9 to 15 VDC (9 VDC
9 to 15 VDC
Table 2 – Indicating LEDs
Ethernet Link
–
Link Established
No Link
EXT Link
CLFE1EOU Only
Pass-Through PoE
No external power required
when in a C1 or C2 rack)
†
Ethernet Activity
EXT LNK
Activity Detected
10Mbps
–
100Mbps
No Activity
No Link
Power
CLFE(X)EO(C,U) SERIES
INS_CLFE(X)EO(C,U)_REV– 10/27/11 PAGE 9