of gas you use (see table in "Techni-
cal Information" chapter).
4.
Assemble the parts, follow the same
procedure backwards.
5.
Replace the rating plate (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this plate in the package supplied
with the appliance.
If the supply gas pressure is changeable
or different from the necessary pressure,
you must fit an applicable pressure ad-
juster on the gas supply pipe.
7.4 Adjustment of minimum level
To adjust the minimum level of the burn-
ers:
1.
Light the burner.
2.
Turn the knob on the minimum posi-
tion.
3.
Remove the knob.
4.
With a thin screwdriver, adjust the by-
pass screw position.
A
A)
The by-pass screw
• If you change from natural gas G20 20
mbar to liquid gas, fully tighten the by-
pass screw in.
• If you change from liquid gas to natural
gas G20 20 mbar, undo the by-pass
screw approximately 1/4 of a turn (1/2
of a turn for Triple Crown burner).
WARNING!
Make sure the flame does not go
out when you quickly turn the
knob from the maximum position
to the minimum position.
7.5 Electrical connection
• Make sure that there is access to the
mains plug after the installation.
• Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
• Do not connect the appliance with an
extension cable, an adapter or a multi-
ple socket. There is a risk of fire. Make
sure that the ground connection com-
plies with the standards and regulations
force.
• Do not let the connection cable parts to
heat to a temperature above 90°C.
Electrical Requirements
Permanent electrical installation must
comply with the latest I.E.E. Regulations
and local Electricity Board regulations. For
your own safety the installation must be
done by a qualified electrician (e.g. your
local Electricity Board, or a contractor
who is on the roll of the National Inspec-
tion Council for Electrical Installation Con-
tracting [NICEIC]).
The manufacturer declines any lia-
bility if these safety measures are
not observed.
The appliance must be connected to a
230 V 50 Hz AC electrical supply.
Before activating the appliance, make
sure the electrical supply voltage is the
same as that indicated on the rating plate.
The rating plate is located on the bottom
of the appliance.
The appliance is supplied with a 3 core
flexible supply cord with a 3 amp plug. If it
is necessary to change the fuse, use a 3
amp ASTA-approved (BS 1362) fuse.
ENGLISH