12 www.electrolux.com
E
A)
Green and Yellow
B)
3 amp fuse
C)
Brown
D)
Cord clamp
E)
Blue
Should the plug need to be replaced for
any reason, the wires in the mains lead
are coloured in accordance with the fol-
lowing code:
Green and yellow
Blue
Brown
1.
Connect the green and yellow (earth)
wire to the terminal in the plug which
is marked with the letter 'E' or the
earth symbol
and yellow.
2.
Connect the blue (neutral) wire to the
terminal in the plug which is marked
with the letter 'N' or coloured black.
3.
Connect the brown (live) wire to the
terminal in the plug which is marked
with the letter 'L' or coloured red.
There must be no cut or stray strands of
wire present. The cord clamp must be
correctly attached on the outer sheath.
WARNING!
Make sure that the cut off plug is
disposed of safely. A cut off plug
put into a 13 amp socket is a
safety hazard. There is a risk of
electrical shock.
A
B
- Earth
- Neutral
- Live
, or coloured green
The replacement of the electrical
cable must be done by a qualified
electrician or competent person,
according to the current regula-
tions.
7.6 Replacement of the
connection cable
C
To replace the connection cable use only
H05V2V2-F T90 or equivalent type. Make
D
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.
7.7 Building In
min. 45 mm
10 mm
A)
supplied seal
B)
supplied brackets
min. 600 mm
min. 450 mm
min. 650 mm
30 mm
830 mm
3 mm
27 mm
B
A
27 mm
A