AirTech ACR35CV Installation And Wiring Instructions - Page 5

Browse online or download pdf Installation And Wiring Instructions for Fan AirTech ACR35CV. AirTech ACR35CV 13 pages.

Menu
If the buttons are pressed the display goes from prism mode to direct view mode and
menu activated. If the buttons are not pressed for 30 seconds the display reverts to
prism mode.
The
(Up) button is used to increase the value of a
setting, the
(Down) button is used to reduce the value
of a setting and the
advance to the next menu item.
The fan has the following 'menu' modes:
 Standard (press any button from normal runtime -
 Advanced/Engineer (hold
 Data-logger readout (hold

Standard settings:

Display 
Configuration 
text 
Option 
r‐n 
Rotate display 
trI 
Trickle speed 
adjustment 
bSt 
Boost speed 
adjustment 
b15 
Boost Overrun 
time 
h70 
Humidity level 
trigger 
F‐0 
Fan Control Mode F‐0 = CV disabled, wall / 
c‐n 
Comfort mode 
unl 
 
Enable / disable 
lock code 
‐‐‐ 
 
 
Menu lock code 
cod 
*If "0" is selected, the fan switches to Intermittent mode.
(Mode/Set) button is used to
+
for 5 seconds from the standard menu)
for 5 seconds from standard menu)
Selections 
r‐Y = display rotated 
100mm: 0*, 5 to 30 l/s (Max limited by Boost Selection) 
100mm: 6 to 35 l/s (Min limited by Trickle Selection) 
b0 to b30 – 0 to 30 minutes (0 disables overrun) 
h40 to h90  ‐ 40% to 90% relative humidity 
window installation 
c‐n = normal LS overrun 
loc ‐ lock code enabled 
Up / down selects current digit, X moves to next digit. 
To change the lock code when "cod" is displayed select the up/down 
buttons to select a digit then select X to move on to the next digit.  
r‐n = display normal 
F‐1 = CV disabled, 
ducted installation 
c‐Y = comfort mode 
unl ‐ lock code disabled 
(unlocked) 
   
)
Default
9l/s 
15 l/s 
70% 
F‐2 = CV Constant 
Volume enabled 
   
10c 
r‐n 
15 
RH 
F‐0 
c‐n 
unl