1) Description of the control unit :
Mode cursor.
2) Fixing the comfort temperature
The comfort temperature is the temperature that you would like while the room is occupied.
a) Put the
cursor to
b) Set the
control knob on 5, the heating indicator V1 comes on if the room temperature is below the required
temperature.
c) Wait a few hours for the temperature to stabilise.
d) If the setting is satisfactory (if necessary use a thermometer to check), mark the position for future use.
e) If the setting is not satisfactory, adjust it and start again from point c.
3) Fixing the Eco temperature :
This is the required temperature during periods when the room is unoccupied. It is recommended that this mode
should be used if the room is unoccupied for no more than 2 hours.
a) Set the
to .
b) This will reduce the temperature of the thermostat by 3°C to 4°C from 2 setting. The heating light V1 comes
on, if the ambient temperature is lower than the Eco temperature.
c) Wait a few hours until the temperature stabilizes.
Note : When switching n°1 (on the picture) is set on Programming system (clock symbol) with the PassProgram
On/Off, please refer to paragraph n°8.
4) Frost-Free mode
This mode is used to keep the temperature at approximately 7°C in the room when you are absent from the house for
a prolonged period (i.e. more than 24 hours).
a) Set the
switch on
5) The heating indicator : V1
This light comes on when the heating element is working. It may flash when the temperature has stabilised.
6) Locking the controls :
It is possible to lock or limit use of the
the panel heater (children, etc.).
a) Unhook the panel heater from its wall mounting.
b) Remove the slugs P on the back of the thermostat from their mountings.
c) Select position B to lock the control knob or position L to limit the amount it can be turned. Position M blocks the switch
for Electronic Model.
7) Using the pilote wire :
The product with pilote wire can receive the following signals from a master unit :
- comfort (temperature of (2) control knob)
- eco (comfort temperature -3°C to -4°C)
- frost free (approximately 7°C)
- off.
Put the switch (1) to the programming mode (clock symbol).
The product must be connected through the pilote wire to a programming control or a product equipped with pass
program system in order to use these different modes. You can control several convectors with a single program-
mer or a product equipped with pass program system.
Warning: When the programme turns to Frost Free or Off in the main programming system or using a Pass Program
system, these functions will override the manual switch of the Panel Heater.
8) Using the On/Off PassProgram system. Ref 602019
When using programming mode (clock symbol) with the on/off pass program system (interface + timer), the moon
symbol on the timer refers to the off mode (no heating).
Warning: When the programme turns to Off using a Pass Program system (ref. 602019), this function will override
the manual switch of the Panel Heater.
- There is no point in setting maximum heating, the room temperature will not rise any quicker.
- When you air the room, disconnect the panel heater by putting the
- If you leave for several hours, remember to reduce the temperature.
Absence for: less than 2 hours, set the cursor
2 to 24 hours, put the
- If you have several units in a room, let them operate simultaneously. This will give you a more uniform
temperature without increasing electricity consumption.
USING THE PANEL HEATER
9 9 9 9 9
Temperature adjustment control knob.
.
.
control knob and lock the

RECOMMENDATIONS FOR USE

control Knob to
V1
Heating indicator light
switch to prevent unauthorised manipulation of
switch to off.
switch knob to moon
.
or off.