Electrolux C290R Service Manual - Page 35
Browse online or download pdf Service Manual for Ventilation Hood Electrolux C290R. Electrolux C290R 41 pages. Hydro-extractor
Also for Electrolux C290R: Operating Manual (24 pages), Operating And Installation Manual (20 pages)
Service
manual
Fault-tracing
Motor does not run at all.
• Check the power supply to the motor. Check the motor´s quick connector.
• Check the motor windings with an ohmmeter for short-circuit or failure.
• Check that the motor shaft can be turned. If it can´t, the probable cause
is bearing failure. Replace the motor.
• If, right after stopping, the motor feels abnormally hot, its thermal protection has
probable tripped. Investigate the cause of the overloading. Check that motor and drum
rotate easily.
The motor protection resets automatically when the motor has cooled, after about 30
minutes. Start the machine and listen for any untoward noise.
If the motor protection trips repeatedly, it may be because of short-circuiting. Bearing
failure in the motor may be the cause.
Motor runs slow
The motor is probably operating on only two phases.
• Check that the motor´s power supply is correct.
• Remove the quick connector and use a meter to check the motor windings for failure or
short-circuiting.
Motor is very noisy or seizes
• Bearing failure, replace motor
487 03 29 91
30. Motors
30
30.3