Electrical connection (not for UK)
Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the voltage indicated on
the rating plate corresponds to the mains power supply available. Appliances fitted with a
plug can be connected to any standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must only be installed by
an electrician authorised by the local electricity board. When installing, an omnipolar
disconnector with a distance of at least 3 mm between contacts must be provided.
Electrical connection
220-240 V – by means of fixed power cable with plug.
(Fixed connection of the appliance must only be carried out by an authorised electrician.)
Electrical connection for UK only
Safety warnings for the electrician
The electric outlet should be placed on the wall inside the chimney. The hood has a
power cable, 150 cm, with earth connection and the rated voltage is 220 - 240 V.
Connect the hood to the mains supply via a double pole switch
which has 3 mm minimum separation between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow must be connected to the terminal which
is marked with the letter E or by the earth symbol (
and yellow;
- the wire which is coloured blue must be connected to the terminal which is marked
with the letter N or coloured black, -
- the wire which is coloured brown must be connected to the terminal which is marked
with the letter L or coloured red.
), or coloured green or green