b. Horizontal Wall Mounting Guide

Installation

Installation must comply with AS/NZS 3500.4.2 and all local codes.
The clearance required needs to be adequate for service/replacement
of cold water inlet piping devices, TPR valve and tempering valve,
elements and thermostats. This may be facilitated by correct orientation
of the cover positions when installing. There are no operational clearance
limitations to surrounding structure. TPR valve removal requires up to
approximately 170-200mm for withdrawal. If the Atlantic Plumbing Cover
(shown to the right) is to be used for aesthetic purposes, please allow 300mm.

Combustible Material

It is recommended not to place combustible material on or adjacent to the water heater.
4