Atlantic ColorFalls CC06 Operating Manual - Page 2

Browse online or download pdf Operating Manual for Lawn and Garden Equipment Atlantic ColorFalls CC06. Atlantic ColorFalls CC06 14 pages. Color changing colorfalls
Also for Atlantic ColorFalls CC06: Operating Manual (14 pages)

Introduction
Thank you for choosing Atlantic's Color Changing Colorfalls. The Colorfalls are
designed for use in Pond-free and fountain applications. The Color Changing
Colorfalls feature a larger opening which produces a thicker water sheer and less
clogging from debris in the water, a remote controlled Color Changing LED light
bar, and a removable back plate that provides access to the interior of the spillway
for easy maintenance and winterizing.
Prior to Operation and Installation
Caution:
• DO NOT operate this product under any conditions other than those for which
it is specified. Failure to observe these precautions can lead to electrical shock,
product failure, or other problems.
• Follow all aspects of electrical codes when installing the Color
Changing Colorfalls.
• To reduce the risk of electrical shock, connect only to a 110 volt receptacle
protected by a ground fault circuit interrupter (GFCI).
• The input power to the Color Changing Control Module is 12 volt AC. The
Control Module can be connected to a larger outdoor lighting transformer;
however this must be done between the Control Module and the transformer.
Removing the Control Module or tampering with the cord between the Control
Module and the Colorfalls will damage the light bar and void warranty.
• The Control Module is weather resistant with an IP54 rating. Do not submerse
the Control Module or expose it to heavy rainfall. It must be mounted off the
ground close to the power source. Failure to do so will void the warranty.
• Colorfalls are designed for use in Pond-free and fountain applications.
Colorfalls are not intended for use in water gardens or any pond with
plant or aquatic life.
The ColorFalls must be accessible for service and maintenance. Installing the
ColorFalls so that the entire body is removable is highly recommended. Do not
glue the cap stones above the ColorFalls or permanently mortar the ColorFalls
in place.
The Colorfalls can support 40 lbs. per linear foot (e.g. a 24" Colorfalls can support
80 lbs.). If the weight on the weir exceeds that amount, you will need to provide a
lintel support for the added weight. This support should still make contact with the
weir to prevent it from shifting.
2
See the chart below for the recommended placement of the Colorfalls above the
basin or pool. If the placement of the Colorfalls exceeds the recommended height,
water loss will increase significantly due to splash and wind drift.
Maximum Falls
Colorfalls
Height Above Basin
CC06
CC12
CC24
CC36
Installation of Color Changing Colorfalls
The opening in the wall where the Colorfalls will be placed is important to the
function of the Colorfalls. If it is not level and free of debris the Colorfalls will not
function properly. The base of Colorfalls body as well as the bottom of the spillway
lip must be supported by the
opening in which it is placed. The
Colorfalls Spillway must protrude
from the wall a minimum of ½"
and maximum of 1". The top side
of the opening must also be in
contact with the Colorfalls to
prevent it from shifting. See Figure
1 for the proper sizing of the
opening for the Colorfalls.
Plumbing A Single Colorfalls
Each ColorFalls spillway is
equipped with three convenient
1½" threaded inlets to
accommodate 1½" Sch 40 MPT
fittings. Choose one or more of
the three inlets for plumbing: you can either plumb directly into the back center
of the unit, or into both sides. (Plumbing the ColorFalls from one side only will
produce an uneven water sheer. Feed lines must be connected to both sides to
ensure an even water flow.) Close off the unused inlet(s) with the provided plugs.
The plugs have O-ring seals and can be installed without thread sealant.
Installing a ball valve (not included) on the feed line between the pump and the
Colorfalls is recommended for added control of water flow.
Flow Rate
18"
600 GPH
24"
1200 GPH
30"
2400 GPH
36"
3600 GPH
Figure 1
½"
4"
3
3
4"
/
"
8
3