Daikin Altherma 3 H HT Installation Manual - Page 14
Browse online or download pdf Installation Manual for Heat Pump Daikin Altherma 3 H HT. Daikin Altherma 3 H HT 20 pages.
6 Finishing the outdoor unit installation
1 2
5.4
To reposition the air thermistor on
the outdoor unit
This procedure is only necessary in areas with low ambient
temperatures.
Required accessory (delivered with the unit):
Thermistor fixture.
2
4
6
Installation manual
14
1
3
5
Click
7
6
Finishing the outdoor unit
installation
6.1
To close the outdoor unit
NOTICE
When closing the outdoor unit cover, make sure that the
tightening torque does NOT exceed 4.1 N•m.
3 2
6.2
To install the discharge grille
Install the lower part of the discharge grille
1 Insert the hooks.
2 Insert the ball studs.
2
1
3 Fix the 2 lower screws.
3
2×
4
1
3
2
3×
4
1
EPRA14~18DAV3+W1
Daikin Altherma 3 H HT
4P586100-1 – 2019.07