Bosch KAN58A40AU Repair Instruction - Page 25
Browse online or download pdf Repair Instruction for Refrigerator Bosch KAN58A40AU. Bosch KAN58A40AU 25 pages.
Also for Bosch KAN58A40AU: Repair Instruction (50 pages)
![Bosch KAN58A40AU Repair Instruction](/uploads/products/server2/1446494/1446494.jpg)
8
TECHNICAL SPECIFICATIONS
8.1
Electrical specifications
Operating voltage:
The operating range of the appliance is between 220 V and 240 V AC.
Operating frequency:
The operating range of the appliance is between 45 Hz and 55 Hz.
Interior light:
AC 230 V, 25 W
Defrosting heater:
AC 220 V, 192 W
Channel heater:
AC 220 V, 7 W
Freezer compartment fan:
DC 13 V, 2050 rpm
Refrigerator-compartment fan:
DC 13 V, 1850 rpm
Condenser fan:
DC 13 V, 1100 rpm
Main fuse:
AC 250 V, 12 A
Thermal fuse:
AC 250 V, 10 A, 77 °C
175_58300000116046_ara_en_h.doc – 12.01.12
Seite 25 von 25