TECHNICAL SPECIFICATIONS

8.1

Electrical specifications

Operating voltage:
The operating range of the appliance is between 220 V and 240 V AC.
Operating frequency:
The operating range of the appliance is between 45 Hz and 55 Hz.
Interior light:
AC 230 V, 25 W
Defrosting heater:
AC 220 V, 192 W
Channel heater:
AC 220 V, 7 W
Freezer compartment fan:
DC 13 V, 2050 rpm
Refrigerator-compartment fan:
DC 13 V, 1850 rpm
Condenser fan:
DC 13 V, 1100 rpm
Main fuse:
AC 250 V, 12 A
Thermal fuse:
AC 250 V, 10 A, 77 °C