Motor Blower Assembly Removal
NOTE
1. Cut off power to the hood unit.
2. The vent grill cover, filter assembly and control
box top cover needs to be removed before the
motor blower assembly can be removed
3. Wear a anti static wrist strap when removing
connections from control PCB.
1. Remove two screws on the electrical
mounting plate wire strain relief. Remove
strain relief.
2. Remove the capacitor connector, motor
connector and grounding connector from the
PCB control board.
Section 4: Component Removal
3. Remove six screws from the motor blower
install bracket.
4. Move the assembly 1cm down along the
installation bracket and then remove the
blower motor assembly.
4-8