Electrolux Icon E36DD75ESS Installation Instructions Manual - Page 12

Browse online or download pdf Installation Instructions Manual for Ventilation Hood Electrolux Icon E36DD75ESS. Electrolux Icon E36DD75ESS 33 pages. External blower assembly for electrolux retractable ventilation systems
Also for Electrolux Icon E36DD75ESS: Installation Instructions Manual (14 pages), Specification Sheet (1 pages), Use & Care Manual (12 pages), Factory Parts Catalog (6 pages), Use & Care Manual (12 pages), Specifications & Dimensions (2 pages), Installation Instructions Manual (14 pages)

Electrolux Icon E36DD75ESS Installation Instructions Manual
12
Duct Preparation
3. Add (1) and (2) to determine the total equivalent straight length of the
complete duct system: 25' + 15' + 4' = 44' total equivalent straight duct length.
4. For the system with 3 ¼" x 10" duct, the maximum allowable total equivalent
straight length of duct is 60 feet. Thus, this proposed installation is proper.
After determining that your proposed duct work meets the maximum duct length
requirement, proceed with the location planning.