Also for Electrolux ICON RH30WC60GS: Factory Parts Catalog (4 pages), Installation, Use & Care Manual (21 pages), Installation, Use & Care Manual (22 pages), Installation, Use & Care Manual (22 pages), Brochure & Specs (2 pages), (Spanish) Guia De Instalación, Uso Y Cuidado (22 pages), (French) Manual D’installation, Utilisation Et D’entretien (22 pages)

Electrolux ICON RH30WC60GS Use & Care Manual
Installing the hood
Making the electrical connections
Metal electrical
conduit
WARNING
Electrical Shock Hazard
Warning: Turn off at the service panel before wiring
this unit.
120 V AC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FI-I-rED WITH AN ELECTRICAL
JUNCTION BOX WITH _, WIRES, ONE OF WHICH
6GREEN/YELLOWl _ SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW
WIRE MUST BE CONNECTED TO THE
GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND IT MUST
UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove junction box cover and knockout on the
top left side.
Knockout
Junction box
cover
House
wiring
UL listed
wire nut
Run black (live), white (neutral), and green
(earth) wires (#14 AWG) according to the
National Electrical Code or CSA Standards and
local codes and ordinances in 1/2" conduit from
power supply to junction box.
°
Connect black, white, and green wires from
power supply to black, white, and green/yellow
wires in junction box respectively.
These connections should be done always
making reference to the electrical diagram found
inside the hood.
Close junction box cover and reapply screws.
If not already done, install 1/2" conduit connector
in junction box.
NOTE: This connector is not included with vent
hood.