Atlantic Ultraviolet Mighty Pure MP13A Owner's Manual - Page 13

Browse online or download pdf Owner's Manual for Water Filtration Systems Atlantic Ultraviolet Mighty Pure MP13A. Atlantic Ultraviolet Mighty Pure MP13A 20 pages. Ultraviolet
Also for Atlantic Ultraviolet Mighty Pure MP13A: Owner's Manual (20 pages)

TROUBLESHOOTING

!
CAUTION:
IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.
Problem
Purifier not operating.
Water leaking into/from
purifier.
Poor purifier performance
AND/OR Low UV intensity
(As indicated on Optional
Guardian™
Ultraviolet Monitor).
Always disconnect power to the water purifier, before performing any service.
Table 3 - Troubleshooting
Possible Cause
No electrical power...
Ballast
Lamp-out Protection
(MP16A, MP22A & MP36C) two (2) minutes to reset.
Cracked or broken
quartz sleeve...
Quartz sleeve sealing
o-ring (s) worn, damaged...
Poor, or loose, connections
or fittings...
Quartz sleeve fouled...
Sensor Probe, if equipped,
lens fouled...
Germicidal lamp output
depreciating...
Germicidal lamp not
functioning...
Low input voltage...
Change in water quality...
Corrective Action
Verify that the purifier is connected to a live power source.
Disconnect the purifier from utility power. Replace lamp.
The purifier must remain disconnected from power for
Shut down purifier, drain, and replace quartz sleeve.
See "Quartz Sleeve Cleaning or Replacement" in the
"Maintenance" section.
Shut down purifier, drain, and remove static gland nut,
replace sealing o-ring. See "Quartz Sleeve Cleaning or
Replacement" in the "Maintenance" section.
Tighten suspect connection or fitting; or shut down
purifier, drain, and remove fitting or connection.
Clean threads; reapply thread sealing tape and reinstall.
Clean quartz sleeve, see "Quartz Sleeve Cleaning
or Replacement" in the "Maintenance" section.
Clean lens or Quartz Rod, see "Optional Ultraviolet
Monitor Sensor Probe Cleaning" in the "Maintenance"
section.
Replace lamp, as it nears its end of life (EOL). See
"Lamp Replacement" in the "Maintenance" section.
Replace lamp. See "Lamp Replacement" in the
"Maintenance" section.
Verify input voltage to purifier.
Have water tested to confirm that it does not exceed
maximum recommended concentration levels for use
with this purifier.
13