INSTALLATION
Standard ducting installation
The rangehood must be positioned at a minimum
clearance of 600mm for an electric cooktop and 650mm
for a gas cooktop. the rangehood should be no further
than 800mm from the cooktop, otherwise the unit
becomes less effective as the distance from the cooking
surface to the rangehood increases.
underside of
rangehood
top of cooking
surface
Fixing point dimensions – 600mm
REHR6* WRH605I* WRH608I*
ø
WRR614SA
ø
if the cooktop
manufacturer
specifies
a greater
600
650
clearance
then that
must be used
121
121
Fixing point dimensions – 900mm
ø 121
WARNING!
Failure to install the screws or fixing device in
accordance with these instructions may result in
electrical hazards.
Ducting installation
When installing with ducting pipe the Duct spigot must
be fitted to the ducting hole on top of the body of the
rangehood.
Recirculating installation
(For Models: WRH608I* WRR614*A & WRH908I*)
When installed in recirculating mode the ducting hole
cover must be fitted.
Parts supplied with hood
1 × Duct Spigot
1 × Ducting hole cover (only for WRH608I*
WRR614*A and WRH908I*)
4 × M6 × 40 screws
4 × Ø6 washers
2 × Carbon filters (only for WRR614*A)
Parts to be purchased
Aluminium tape or cable ties to secure flue pipe
Custom drawer fascia (if required)
Ducting accessories
Duct Spigot
Ducting hole cover