CP400 & CP700 COMMERCIAL
POWER AMPLIFIER
INPuT WIRINg
Balanced Inputs
Balanced input wiring requires two conductors with shield (22-gauge is the most common). The use of
crimp type spade lugs is highly recommended for permanent installations. At the input section located on
the rear of the amplifier, wire the "hot"/positive lead to the "+" terminal, the "common"/negative lead to the
"-" terminal and the shield/drain to the "ground" terminal (Figure 3).
The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female patch
cables to accommodate outputs from a mixer, equalizer, or crossover when the amplifier is used as a
portable sound system amplifier.
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •
©2008 ATLAS SOUND LP
White (+)
Black (-)
Shield
Specifications are subject to change without notice
AtlasSound.com
Printed in U.S.A.
OWNER'S MANUAL
White (+)
Black (-)
Shield
TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
ATS002102 RevD 2/08
Figure 3
PP
7