Atlas CP400 Owner's Manual - Page 7

Browse online or download pdf Owner's Manual for Amplifier Atlas CP400. Atlas CP400 16 pages. Commercial dual channel power amplifiers
Also for Atlas CP400: Brochure & Specs (10 pages), Owner's Manual (16 pages), Owner's Manual (16 pages)

Atlas CP400 Owner's Manual
CP400 & CP700 COMMERCIAL
POWER AMPLIFIER

INPuT WIRINg

Balanced Inputs
Balanced input wiring requires two conductors with shield (22-gauge is the most common). The use of
crimp type spade lugs is highly recommended for permanent installations. At the input section located on
the rear of the amplifier, wire the "hot"/positive lead to the "+" terminal, the "common"/negative lead to the
"-" terminal and the shield/drain to the "ground" terminal (Figure 3).
The XLR inputs (+4 dB balanced line level) can be utilized with standard 3-pin XLR male to female patch
cables to accommodate outputs from a mixer, equalizer, or crossover when the amplifier is used as a
portable sound system amplifier.
1601 JACK MCKAY BOULEVARD ENNIS, TEXAS 75119 U.S.A. •
©2008 ATLAS SOUND LP
White (+)
Black (-)
Shield
Specifications are subject to change without notice
AtlasSound.com
Printed in U.S.A.
OWNER'S MANUAL
White (+)
Black (-)
Shield
TELEPHONE: (800) 876-3333 • FAX: (800) 765-3435
ATS002102 RevD 2/08
Figure 3
PP
7