Troubleshooting
Problem
The power tool does not start.
The power tool switch trips out.
The fl exible shaft is overheating.
The power tool vibrates too much.
The power tool is very noisy
The vibrating poker does not vibrate but
the power tool starts.
© 2015 Construction tools PC AB | No. 9800 1713 01 | 2015-04-07
Original instructions
Cause
The plug is not connected.
Start switch is in off position.
The carbon brushes are worn out.
No power in the power socket.
Defective power switch
The internal vibrator is overloaded (when
operating in concrete or rebar).
Air inlet or outlet is clogged and the power
The electric motor fan is broken and the
power tool is not cooled.
Nuts and bolts fi xating the outer casing has
Tighten the nuts and bolts. come loose.
Too much friction in the fl exible shaft.
Too much grease on the fl exible shaft.
Too much torque inside the the vibrating
poker (the bearings get worn out).
Too much friction in the fl exible shaft.
The bearings of the power tool are worn
out.
Too much friction in the fl exible shaft.
The carbon brushes are worn out.
The bearings are defective.
The rotor is touching the stator.
The outer cladding is broken or has loose
The bearings in the in the vibrating poker
are broken.
The fl exible shaft is broken.
Safety and operating instructions
Solution
Connect the electrical plug into a power
socket.
Turn the switch on.
Change the carbon brushes.
Replace or repair the power socket.
Replace the power switch.
Raise the the vibrator poker from the
concrete and immerse it again.
Remove anything that may obstruct the air
tool is not cooled.
Replace the fan at an authorised
workshop.
Grease the fl exible shaft in the hose.
Respect the quantity of 15 grams per
meter of fl exible shaft.
Replace the bearings in the vibrating
poker.
Grease the fl exible shaft in the hose.
Replace the bearings in the power tool at
an authorised workshop.
Grease the fl exible shaft in the hose.
Change the carbon brushes.
Replace the bearings.
Replace the rotor at an authorised
workshop.
Inspect the cladding and tighten the bolts.
bolts
Replace the bearings in the in the
vibrating poker.
Replace the fl exible shaft.
15