Advanced Quality Industries IntegrAlarm IA-FOB-1 User's And Installer's Manual - Page 6
Browse online or download pdf User's And Installer's Manual for Security System Advanced Quality Industries IntegrAlarm IA-FOB-1. Advanced Quality Industries IntegrAlarm IA-FOB-1 8 pages. 5-function keyfob
2.3 Installation
Installation of each multifunction keyfob is a two-step procedure. The multifunction keyfob
should first be registered via the IntegrAlarm Control Panel. It should then be tested to
confirm that it operates properly.
2.3.1 Registration
From Installer Menu on Control Panel, select ENROLL. Screen will show:
ENTER ZONE #
Use numeric keypad at right of Control Panel to enter the desired zone number. The
description of the zone number (e.g. MASTER BEDROOM) will appear at bottom of
screen. If zone description is correct, press OK at left of Control Panel. Screen will show:
PLEASE POWER UP
Insert battery. The remote control will begin to transmit. If Control Panel does not identify
the remote control, screen will show:
ZONE NOT FOUND
If Control Panel identifies the remote control, Control Panel will emit an audible beep and
screen will show:
S/N: XXXXXX
where XXXXX is the multifunction keyfob serial number and YYYY is REMOTE. Ensure
that the serial number displayed corresponds to the serial number of the multifunction
keyfob and press OK at left of Control Panel. Screen will show:
ACCEPT ZONE DATA
NO
Press OK at left of Control Panel.
System will update zone enable parameters, multifunction keyfob serial number and type,
and mode of operation (A, B or C).
2.3.2 Testing
When the multifunction keyfob has been registered and installed, test it by performing
each of the following tests:
• Standing near the Control Panel, press HOME. Ensure that the LED first
flashes red (indicating transmission to the Control Panel) and then green
(indicating receipt of ACK response from the Control Panel). Observe
Control Panel display to ensure that the IntegrAlarm System enters
Document # E.0015.16.05
THE ZONE
TYPE: YYYY
YES
396194