Atlas Copco PHE 3X Repair Instruction - Page 7
Browse online or download pdf Repair Instruction for Drill Atlas Copco PHE 3X. Atlas Copco PHE 3X 14 pages.
Removing the
1 Remove the air deflector plate (5) and the
field
silicone buffer (4).
2 Pull the field (2) from the field housing (1)
and remove the centering ledges (3).
Maintenance
General
It is recommended to regularly submit the tool to maintenance. Maintenance is also due if the carbon
brushes cut off or if the hammer mechanism fails. When carrying out maintenance all parts of the
maintenance set must be exchanged. Use the appropriate maintenance set for
each machine: PHE 3:
Torque
Position
1
2
3
4
5
6
7
8
Cleaning
With the exception of the electrical parts all parts must be cleaned with cold cleaner. Attention! No
cleaner must enter the encapsulated bearings.
Clean the electrical parts with a dry brush.
Abrasion test
Check the dismantled parts for abrasion (visual check) and exchange if necessary.
4931 3568 29 (220-240 V), 4931 3568 37 (110 V)
PHE 3 X: 4931 3568 38 (220-240 V), 4931 3568 40 (110 V)
1
2
3
4
5
6
Name
Handle cover screws
Motor screws
Spindle sleeve screws
Joining gear housing/motor housing
Motor screws
Motor cover screws
Handle bolt
Strain relief mains cable
Repair Instruction No. 175.8/95
1
2
3
4
5
Torque
1,2
Nm
2,5
Nm
6,0
Nm
2,5+5 Nm
2,5
Nm
1,8
Nm
10,0
Nm
1,0
Nm
PHE 3, PHE 3X
7
8
PAGE
7
1 8