Bose FreeSpace ZA 2120-HZA Installation And Operation Manual - Page 37
Browse online or download pdf Installation And Operation Manual for Amplifier Bose FreeSpace ZA 2120-HZA. Bose FreeSpace ZA 2120-HZA 48 pages. Integrated / zone amplifiers
- 1. Table of Contents
- 2. Freespace® Iza 2120-Lz / Iza 2120-Hz Integrated Zone Amplifier
- 3. Iza 2120-Lz Rear Panel
- 4. Za 2120-Lza/Hza Rear Panel
- 5. Remote Volume Control
- 6. Connecting the CC-1 to a Freespace® Amplifier
- 7. Connecting an Iza 2120-Lz/Hz Amplifier to a Za 2120-Lza/Hza Amplifier
- 8. Troubleshooting
pro.Bose.com
Amplifier rated channel power is 120 W.
Test Signal & Power Level
Power On, Idling
1/8th Rated Power
IEC268 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
1/3rd Rated Power
IEC268 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
Test Signal & Power Level
Power On, Idling
1/8th Rated Power
IEC268 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
1/3rd Rated Power
IEC268 Bandlimited Pink Noise
6 dB Crest Factor
DS 16 EQ Enabled
Additional Information
Refer to the owner's guide (online at pro.Bose.com) for more information about your product (including
accessories and replacement parts). To request a printed copy, use the phone numbers provided.
Limited Warranty
Your product is covered by a limited warranty. Visit pro.Bose.com for warranty details.
The warranty information provided with this product does not apply in Australia and New Zealand. See
our website at www.bose.com/au/warranty or www.bose.com/nz/warranty for details of the Australian
and New Zealand warranty.
Date of Manufacture
The eighth digit in the serial number indicates the year of manufacture; "6" is 2006 or 2016.
ZA 2120-LZA, AC Current Draw and Thermal Dissipation
Load Configuration
Total Audio
(Both IZA channels
Output, W
driven)
8Ω/Ch
4Ω/Ch
8Ω/Ch
4Ω/Ch
ZA 2120-HZA AC Current Draw and Thermal Dissipation
Load Configuration
Total Audio
(Both IZA channels
Output, W
driven)
70V/Ch
100V/Ch
70V/Ch
100V/Ch
120 VAC 60 Hz
Line Current, A
0
0.15
15
0.33
30
0.52
40
0.57
80
1.00
120 VAC 60 Hz
Line Current, A
0
0.20
30
0.50
30
0.60
80
1.10
80
1.10
Technical Information
Thermal Dissipation, Max
230 VAC 50 Hz
Line Current, A
Watts
BTU/hr
0.11
25
0.19
29
0.28
34
0.31
31
0.56
49
Thermal Dissipation, Max
230 VAC 50 Hz
Line Current, A
Watts
BTU/hr
0.14
32
0.30
37
0.30
41
0.60
58
0.60
58
Installation Guide - 37
kCal/hr
86
22
98
25
117
30
107
27
167
42
kCal/hr
110
28
125
32
141
36
198
50
198
50