00_Cavu.book Page 33 Thursday, October 28, 2010 12:03 PM
English
Tab 2, 10
Helicopter (U174) connection diagram
Existing wiring to
helicopter intercom/
audio panel
Note: Barrel ground (gnd) refers to aircraft grounds.
Details on making the connections
The pinouts for the optional installed connector are detailed in the table below:
Pin number
Color
1
Red
2
Black
3
White
4
Blue
Note: For stereo operation, connect the left and right channels to their respective positions. For
monaural operation, connect pins 3 and 4 together, and to the tip of the existing phone jack.
5
White
6
White/
Blue
Note: If the microphone works on radio transmit but not through the intercom, check pin 6. It
may be incorrectly wired to the PTT segment of the microphone jack.
Comm Shield
Black
Mic Shield
Black
Note: The wires connecting pins 3 and 4 and pins 5 and 6 are shielded, twisted pairs with a
black wire shield termination exiting each pair. If the existing wiring is not shielded, connect the
shields to the existing audio wiring shields, or connect the shield from Comm L and Comm R
wire pair to audio ground.
Tab 3, 11
Tab 4, 12
WHT/BLU
6
MIC LO
WHT
5
MIC HI
BLU
4
COMM R
WHT
3
COMM L
BLK
2
GND
RED
10-32
1
V+IN
1/2A
V DC
Existing single 4-
prong jack
Barrel
(audio gnd)
Purpose
V+IN: Headset power (10-32 VDC). Use a
a
1
/
amp circuit breaker.
2
GND: System ground. Connect to the existing audio ground.
COMM L: Phone communication: Left.
COMM R: Phone communication: Right.
MIC HI: Microphone/Hi-audio. Connect to the portion of the
existing microphone jack that corresponds to the ring
position of a headset microphone plug. Do not connect to
the tip (PTT) segment.
MIC LO: Microphone/Lo-ground. Connect to the portion of
the microphone jack that corresponds to the barrel position
of a headset microphone plug.
Shield from Comm L and Comm R wire pair.
Shield from Mic Hi and Mic Lo wire pair.
Tab 5, 13
Tab 6, 14
Tab 7, 15
Tab 8, 16
I
NSTALLATION
1
/
amp fuse or
4
33