7.
Refit the end seal fitting as follows:
CAUTION
Only use end seals which are especially designed for this type of heating tapes
①
Uncover the braid by removing the jacket to 13mm length.
Remove the 13mm of exposed braid.
②
Cut a V-shape at the end of the heating tape with a depth of 10mm.
③
Squeeze end seal from the side (see drawing) and fill with silicone.
④
Push end seal over the end of heating tape so that it overlaps the jacket.
⑤
The silicone will set up within 30 minutes with a complete cure after 24 hours.
CAUTION
Do not carry out any dielectric test or measurement of insulation resistance until the
silicone is completely cured.