DROPSA VIP4 Tools Operating And Maintenance Manual - Page 2
Browse online or download pdf Operating And Maintenance Manual for Lubrication systems DROPSA VIP4 Tools. DROPSA VIP4 Tools 17 pages.
1. INTRODUCTION
This operating and maintenance manual refers to the VIP4Tools/Air air/oil lubrication system.
We recommend storing the manual for safe keeping so that it will not be easily damaged over time and to always make it
available to personnel wishing to consult it.
Other copies, updates or clarification of this manual can be requested by contacting the DropsA Technical Sales Office
directly.
The manufacturer reserves the right to update the product and/or operating and maintenance manual without any obligation
to revise the previous versions. In any case, the most recent version available can be requested from the Technical Sales
Office or by consulting our website http://www.dropsa.com.
Operation of the equipment described in this manual must be entrusted to qualified personnel with basic mechanical,
hydraulic and electrical knowledge.
It is the installer's responsibility to install suitable piping for the system. The use of unsuitable piping may generate problems
with the pump, damage to people and cause pollution.
The loosening of the connections may cause serious safety problems. Check them before and after installation and, if
necessary, tighten them.
Never exceed the maximum permitted operating pressure value for the panel and the components connected to it.
Before carrying out any maintenance or cleaning operation, disconnect the electrical power, close the air supply and
discharge the pressure within the equipment and the piping connected to it.
Do not subject the panel, the fittings, the pipes and the parts under pressure to violent bumps. Damaged pipes or fittings are
dangerous. Replace them.
After long periods of inactivity, check the seal on all the parts subject to pressure.
Personnel must use protection equipment, clothing and tools needed in relation to the location and the use of the panel both
during operation and maintenance.
The integrity of the panel and any installed accessories must be checked straight away upon receiving it. For any complaints,
contact the DropsA SpA sales office immediately.
Dropsa SpA will not be liable for any damage to persons or objects in the event of failure to observe the indications in this
manual.
Any modifications to the parts that make up the system or any different use of it or its parts without the written authorisation
of DropsA SpA release the same from any liability for damages to persons and/or objects and exonerate them from the
warranty obligations.
2. GENERAL DESCRIPTION
The VIP4Tools manual must be used for applications on spindle, without control on machines for lubrication of tools and
chains.
Designed for high performance with low cost, it is distinguished by its compactness.
The system is made up of a pneumatically controlled mini-pump and the mixer base. Mini-pumps are manually adjustable in
order to cover any possible need
(0-30 mm³). The modular design of the system makes it extremely versatile; up to a maximum of 8 mixer bases can be
installed. The system can be timed by applying the pneumatic pulse generator kit, P/N 3132572 or controlling it from the
machine PLC.
3. IDENTIFYING THE MACHINE
A yellow label is located on the front part of the oil reservoir that indicates the product code and the basic characteristics.
4. TECHNICAL CHARACTERISTICS
CHARACTERISTICS
Air supply pressure
Operating temperature
Humidity
Lubricants
Oil Viscosity at Working Temperature
Conservation Temperature
SAMBA LEVEL
Temperature:
VIP4Tools/Air lubrication panel
5 ÷ 8 bar (73.5 ÷ 117.6 psi)
-5 ÷ +55 °C (+23 °F ÷ 131 °F)
90% max
Mineral - synthetic
32 ÷ 320 cSt (150 ÷ 1480 SUS)
-20 ÷ +65 °C (-4 °F ÷ 149 °F)
-10°C ÷ +80°C (+14 °F ÷ +176 °F)
2