NOTE:
If plastic pipes are to be heated, then the self-adhesive tape should be
used under the cable. The use of aluminium adhesive tape ensures that
the cable adheres to the pipes securely and accurate heat transmission is
facilitated. The tape also prevents the cable from being pushed into the
thermal insulation, which could cause possible overheating.
STAGE 4
The pipes and heating cables must be insulated. To enable correct operation
of the system the insulation should be at least 10 mm thick though should not
exceed a max.
provided on the thermostat.
of 20 mm thickness. Thermal insulation should also be
9