Anly H5KLR User Manual
Browse online or download pdf User Manual for Cash Counter Anly H5KLR. Anly H5KLR 2 pages. Multi-function digital counter
H5KLR
MULTI-FUNCTION DIGITAL COUNTER
User's Manual
RESTRICTIONS ON USE
When using this product in applications
that require particular safety or when
using this product in important facilities,
please pay attention to the safety of the
overall system and equipment. Install fail-
safe mechanisms, perform redundancy
checks and periodic inspections and
adopt other appropriate safety measures
when it is necessary.
SPECIFICATIONS
Operating voltage
AC/DC : 12
48V / AC/DC : 100
Allowable operating
85 ~ 110% of rated operating voltage
voltage range
Rated frequency
50 / 60Hz
250VAC 5A (Resistive load)
Contact rating
Count speed
MAX 30 cps or 1,000 cps
Power consumption
Approx. 2.5VA
Mechanical : 5,000,000 times / Electrical : 100,000 times
Life
Ambient temperature
-10
+50°C
Ambient humidity
MAX 85% RH
Weight
Approx. 120g
POWER ON
SPECIAL FUNCTION KEY
PRESS FOR 3s
ON / OFF Key
protect
(1)Stop
Switch to input setting mode
INPUT MODE
Change
the mode
Switch to output
setting mode
OUTPUT MODE
Change
the mode
Switch to output 2 time
setting mode
OUTPUT 2 TIME
Change
the set value
Switch to output 1 time
setting mode
OUTPUT 1 TIME
Change
the set value
Switch to count speed
setting mode
COUNT SPEED
Change
the set value
Switch to reset time
setting mode
SAFETY PRECAUTION
WARNING
CAUTION
Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has
been correctly wired before turning the power ON.
Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause
electric shock.
Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.
Do not disassemble the product. Doing so might cause electric shock or faulty operation.
Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage,
shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.
Firmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.
240V
SETTING PROCEDURE
or
RESET
Reset
PRESS FOR 3s
RESET
Switch to input setting mode
(2)Counting
PRESS
RESET
or
FOR 3s
Switch to input setting mode
UP
UP/DOWN A
DOWN
UP/DOWN B
UP/DOWN C
UP/DOWN MODE not available on ASK-4DR , H5KLR-8/-11 type
Save and back to the
RESET
or
operation mode
Mode N
Mode R
Mode Q
Mode F
Mode K
Mode A
Mode C
Mode P
See reverse page for more details
Save and back to the
RESET
or
operation mode
0.01s
0.2s
2s
0.05s
0.5s
5s
0.1s
1s
10s
Not available for Mode N and Mode F
Save and back to the
RESET
or
operation mode
Hold
0.1s
1s
0.01s
0.2s
2s
0.05s
0.5s
5s
Available on H5KLR-11 type only
Save and back to the
RESET
or
operation mode
30 cps
1k cps
Save and back to the
RESET
or
operation mode
Pr od uc t i s s ubj ec t t o c h an ge w i t ho ut n o ti ce .
This manual uses the following symbols to ensure safe operation of this timer.
Warnings are indicated when mishandling this product might result in death or serious injury
to user.
Cautions are indicated when mishandling this product might result in minor injury to the user,
or only physical damage to the timer.
NAMES AND FUNCTIONS OF FACEPLATE
LEDs
RUN: Counting indicator
OUT1: Control output 1 indicator
OUT2: Control output 2 indicator
RESET: Reset indicator
CP1: Signal input 1 indicator
CP2: Signal input 2 indicator
Set1: 1st set value indicator
Set2: 2nd set value indicator
K/P: Key protection indicator
key :
RESET
Reset the output or save the value
of setting.(after save than back to
the operation mode)
MINIMUM RESET TIME
Change
the set value
PRESS
Switch to the position of
decimal point setting mode
FOR 3s
DECIMAL POINT
Move the decimal
point position
Switch to prescale value
PRESCALE VALUE
Change
the set value
Switch to key protection level
20s
KEY PROTECTION LEVEL
Change
the set level
Switch to power off
10s
20s
POWER OFF MODE
WARNING
CAUTION
Upper display
H5KLR
Display PV values (current count values,
etc.) or setup items.
RUN
OUT1
Lower display
OUT2
Display SV values (set count values, etc.)
RESET
Set1
and other parameter values.
CP1
Set2
CP2
K/P
key :
Performing arithmetic shift operations and
RESET
switches the display. Hold down for at least
3 seconds to enter setting modes.
key :
Used for incrementing or decrementing
numeric values. And show the first set value
or second set value.
20ms
1ms
RESET
or
9999
999.9
99.99
RESET
or
setting mode
0.01~9.99
Changing the digit
of prescale value
RESET
or
setting mode
Lock function key
Lock reset key
RESET
Lock preset value key
Lock all key
RESET
or
setting mode
Power off reset
Power off memory
Change
the mode
Switch to Input
RESET
or
setting mode
Save and back to the
operation mode
Save and back to the
operation mode
Save and back to the
operation mode
Save and back to the
operation mode
Save and back to the
operation mode